Blood Culture

Blood Culture image

Pathology category

Microbiology

Code

BC

Referral code

Request form

Test information

CORRECT SPECIMEN TYPE & METHOD OF COLLECTION

Disinfect the skin at the venepuncture site with isopropyl alcohol and allow to dry for at least 30 seconds. Disinfect the septum of the blood culture bottle with isopropyl alcohol and allow to dry. Using your dominant hand hold the blood collection set by pinching the wings together and insert the needle smoothly, with the bevel end uppermost at an approximately 15- 30-degree angle, advance the needle approximately 1cm until flashback is seen. Holding the blood culture bottles upright, glide the adapter cap to pierce the rubber cap. Obtain a maximum of 10mls of blood into blue aerobic bottle first. Then obtain a maximum of 10mls of blood into purple anaerobic bottle. Sample volume should ideally not be less than 5ml for each bottle. Invert bottles once. Any remaining blood tests may then be obtained into specimen tubes for other tests using the insert adapter, if available, or by locating the blood tube bung over the needle located in the centre of the adapter cap. Correct order of draw should be maintained. Remove needle from vein and then apply pressure to venepuncture site using gauze swab. Samples should not be taken through an intravenous catheter or other access device unless no other access is available. When line associated infection is suspected, cultures should be taken from both catheter lumen(s) and peripheral vein. Any materials used in taking these samples must be discarded in an approved clinical waste or sharps container.

Please use the small PAS non-barcoded Patient ID labels, and place on all bottles submitted. Alternatively, the analyser will accept hand-written patient’s details in the space provided on the bottle. This also applies to paediatric blood cultures. Under no circumstances remove the Bottle barcode label as the instrument requires this to identify the sample under processing. If these instructions are not followed, then delays may occur to the sample being loaded and processed. Tests performed in a UKAS Accredited Medical Laboratory No. 8873

Guidelines

Blood Culture Bottle Labelling

Pre-analytical

Do NOT remove barcodes from bottles or obscure with patient label – these are required for the automated analyser. Blood cultures should be transported to the laboratory for incubation immediately. Where there is a delay in transport to the laboratory and/or loading onto the automatedsystem, blood cultures should be stored at room Temperature (21-250C) and must not be refrigerated by porters or ward staff. The incubator in the corridor next to Specimenreception is switched off and so operates at room temperature.Please note that we now use plastic bottles and these specimens can be sent via the air pod. Treat these specimens as urgent sample and send as soon as possible.

Reference range

Tube type

Standard blood culture set (1 purple anaerobic bottle and 1 blue aerobic bottle)

Tube type info

Standard blood culture set (1 purple anaerobic bottle and 1 blue aerobic bottle)

Special requirements

Whole blood

Minimum volume

Up to but no more than 10ml per bottle

Assay frequency

TAT Inpatient (urgent)

2 day negative. Positive cultures as flagged. All positives telephoned. Most patients will be reviewed by a microbiologist on the day the blood culture becomes positive.

TAT Inpatient

TAT GP/Outpatient

2 day negative. Positive cultures as flagged. All positives telephoned. Most patients will be reviewed by a microbiologist on the day the blood culture becomes positive.

Referral lab

Local